--- title: "Import" output: rmarkdown::html_vignette vignette: > %\VignetteIndexEntry{Import} %\VignetteEngine{knitr::rmarkdown} %\VignetteEncoding{UTF-8} --- ```{r, include = FALSE} knitr::opts_chunk$set( collapse = TRUE, comment = "#>" ) ``` # Introduction This vignette gives an overview about importing files for downstream analysis with **mpwR**. ## Import Importing the output files from each software can be easily performed with `prepare_mpwR`. Please put all output files in one folder and follow the guidelines for naming the files. No other files/subfolders are allowed. ```{r import, eval=FALSE} files <- prepare_mpwR(path = "Path_to_Folder_with_files") ``` ## Naming Files The software output files need to be named according some simple rules. ### Suffix Please use the following suffixes for the corresponding software: * Spectronaut * *.tsv - _Report * MaxQuant * evidence.txt - _evidence * peptides.txt - _peptides * proteinGroups.txt - _proteinGroups * DIA-NN * *.tsv - _Report * ProteomeDiscoverer * PSMs.txt - _PSMs * PeptideGroups.txt - _PeptideGroups * Proteins.txt - _Proteins * ProteinGroups.txt - _ProteinGroups Note that the suffixes for MaxQuant and ProteomeDiscoverer can be used as is. ### Prefix Please use the same prefix for your analysis and the respective software output file(s). Each analysis needs a unique identifier. Examples: * Spectronaut * WorkflowA1_Report.tsv * MaxQuant * WorkflowA2_evidence.txt * WorkflowA2_peptide.txt * WorkflowA2_proteinGroups.txt * DIA-NN * WorkflowA3_Report.tsv * ProteomeDiscoverer * WorkflowA4_PSMs.txt * WorkflowA4_PeptideGroups.txt * WorkflowA4_Proteins.txt * WorkflowA4_ProteinGroups.txt ## Handling Error Messages Subsequently, common error messages are explained and solutions are pointed out.

 

 

### Wrong suffix Error in prepare_mpwR(path = path) : Unknown file suffix detected! Please use: _evidence, _peptides, _proteinGroups, _PSMs, _Proteins, _PeptideGroups, _ProteinGroups, _Report

 

Solution: Check your suffixes and make sure to use the correct spelling and the correct one for the respective software.

 

 

### Wrong number of files Error in prepare_mpwR(path = path) : Wrong number of analyses detected for WorkflowA2! MaxQuant requires 3 input files. Remember: Use unique name for each analysis.

 

Solution: Make sure to include all output files from the respective software. MaxQuant requires 3 files, PD 4 files, DIA-NN and Spectronaut 1 file, respectively. Also use the same name (prefix) for all files.

 

 

### Subfolder Error in data.table::fread(input_file, ...) : File 'DIR//subfolder' is a directory. Not yet implemented.

 

Solution: Do not use subfolders in the directory of the output files. Put all files in a folder and use this path for prepare_mpwR.

 

 

### Same file name Error in prepare_mpwR(path = path) : Please use a unique filename for each analysis.

 

Solution: Please use a unique name (prefix) for each respective output file(s). E.g. if you used...: * WorkflowA1_Report.tsv * WorkflowA1_evidence.txt * WorkflowA1_peptide.txt * WorkflowA1_proteinGroups.txt ... the error message is displayed. As a solution, for example add the used software to the name: * WorkflowA1_Spectronaut_Report.tsv * WorkflowA1_MQ_evidence.txt * WorkflowA1_MQ_peptide.txt * WorkflowA1_MQ_proteinGroups.txt

 

 

### Missing columns Error in prepare_input(ordered_files[[i]][["data"]][["DIA-NN"]], software = "DIA-NN") : Not all required columns present in submitted data. Here example for DIA-NN. Similar messages for other software tools. Please make sure to include all required columns for the used software. Details are in the vignette [Requirements](https://okdll.github.io/mpwR/articles/Requirements.html).